Datalogic Scanning LASER SCANNER DS4300 User Manual
Page 53
![background image](/manuals/74845/53/background.png)
DS4300
DATALOGIC
5.2 – Technical Features
SOFTWARE FEATURES
READABLE CODE SYMBOLOGIES
•
EAN/UPC
•
Code
93
•
2/5 Interleaved
•
Code
128
•
Code 39
•
EAN
128
•
Codabar
•
Pharmacode
CODE SELECTION
up to six codes during one reading phase
DECODING SAFETY
can enable multiple good reads of same code
HEADERS AND TERMINATORS
up to four headers and four terminators
OPERATING MODES
ON LINE
,
AUTOMATIC
,
SERIAL ON LINE
,
TEST
CONFIGURATION MODES
•
through menus using WinHost utility
•
receiving commands from one of the serial
ports (HOST MODE)
PARAMETER STORAGE
Non-volatile internal memory
ENVIRONMENTAL FEATURES
Operating temperature (Note 3)
0 to 40
°
C (32 to 104 °F)
Storage temperature
-20 to 70
°
C (-4 to 158 °F)
Humidity max.
90% non condensing
Vibration resistance
IEC 68-2-6 test FC 1.5 mm;
10 to 55 Hz; 2 hours on each axis
Shock resistance
IEC 68-2-27 test EA 30G;
11 ms; 3 shocks on each axis
Protection class
IP65
PHYSICAL FEATURES
Mechanical dimensions
101 x 83.5 x 42 mm (3.97 x 3.29 x 1.65 in.)
Weight
about 800 g. (28.2 oz.)
Note 1:
The features given are typical at a 25
°
C ambient temperature (if not otherwise
indicated).
Note 2:
Further details given in paragraphs 3.3 and 3.4.
Note 3:
If the reader is used in high temperature environments (over 35
°
C), use of the Beam
shutter is advised (for details refer to the WinHost Help On Line).