Installation - 2.5

2.3.2 Junction Box Electrical Connections

The connection and wiring procedure for the junction box is described as
follows:

1) Open the junction box by unscrewing the 4 cover screws.

2) Pass all System cables through the glands in the junction box housing.

3) To connect the power and input/output signals:

Prepare the individual wires of the system cables by stripping the

insulation back approximately 11 mm.

Using a device such as a screwdriver, push down on the orange

lever directly above the clamp (see Figure 2.6).

Insert the wire into the clamp and release the lever.

The wire will now be held in the spring clamp.

Figure 2.6 - System cable connections to the junction box

The wiring used can be solid or stranded but must meet the following
specifications.

Positions 1-4:

24 - 16 AWG

0.2 - 1.5 mm²

Positions 5-39:

26 - 20 AWG

0.14 - 0.5 mm²

The junction box pinouts are indicated in the following table: