2.18 - Installation

18/6/14 +

19/10/15 -

+ 5V

DS4300

USER INTERFACE

V

Signal

Ground

30 Vdc max.

Vext

Figure 2.22 - Input PNP command using external power

18/6/14 +

19/10/15 -

USER INTERFACE

DS4300

VS

9

25

GND

V

Signal

+ 5V

Figure 2.23 - Input PNP command using DS4300 power

The electrical features of the inputs are:

Maximum voltage = 30 Vdc

Maximum current = 25 mA.

An anti-disturbance hardware filter is implemented on the External Trigger
input (< 5 milliseconds delay).

An additional 15 ms (typical) delay can be implemented through a dedicated
software parameter (refer to WinHost Help On Line).