20 ma current loop (int-24 accessory only) – Datalogic Scanning LASER SCANNER DS4300 User Manual
Page 30
DATALOGIC
DS4300
Installation - 2.15
20 mA Current Loop (INT-24 Accessory Only)
When the INT-24 accessory board is installed, the DS4300 is equipped with
a 20 mA active current loop interface.
The following pins of the 25-pin connector are used for the connections:
Pin
Name
Function
4
CLOUT-
current loop output
5
CLIN-
current loop input
7
SGND Main
signal ground main interface
DS4300/DS4600
USER INTERFACE
MAX. 300 METERS
4
C.L. OUT-
7
SGND Main
GND
I = 20 mA
5
C.L. IN-
I = 20 mA
+
+
Figure 2.18 - 20 mA active C.L. connections
For 20 mA passive current loop interface connections, contact your local
Datalogic representative.