20 mA Current Loop (INT-24 Accessory Only)

When the INT-24 accessory board is installed, the DS4300 is equipped with
a 20 mA active current loop interface.

The following pins of the 25-pin connector are used for the connections:

Pin

Name

Function

4

CLOUT-

current loop output

5

CLIN-

current loop input

7

SGND Main

signal ground main interface

DS4300/DS4600

USER INTERFACE

MAX. 300 METERS

4

C.L. OUT-

7

SGND Main

GND

I = 20 mA

5

C.L. IN-

I = 20 mA

+

+

Figure 2.18 - 20 mA active C.L. connections

For 20 mA passive current loop interface connections, contact your local