beautypg.com

3 auxiliary rs232 interface, 4 inputs – Datalogic Scanning LASER SCANNER DS4300 User Manual

Page 31

background image

DS4300

DATALOGIC

2.16 - Installation

2.4.3 Auxiliary RS232 Interface

The auxiliary serial interface is used exclusively for RS232 point-to-point
connections.

The parameters relative to the auxiliary interface (baud rate, data bits, etc.)
as well as particular communication modes such as Local Echo can be
defined using the WinHost utility program or Host Mode programming. For
more details refer to paragraph 2.6 and to the section "Auxiliary Interface
Menu" in the WinHost Help On Line.

The following pins of the 25-pin connector are used to connect the RS232
auxiliary interface:

Pin

Name

Function

20

RXAUX

auxiliary RS232 received data

21

TXAUX

auxiliary RS232 transmitted data

23

SGND Aux

signal ground auxiliary interface

SGND

DS4300

USER INTERFACE

TXD

RXAUX

20

RXD

TXAUX

21

SGND Aux

23

Figure 2.19 - RS232 auxiliary interface connections

2.4.4 Inputs

There is an input available on the DS4300 scanner relative to the External
Trigger.

There are also 2 general purpose inputs:

IN1 can be used to store the code verifier (see "Store verifier HW" in the
Winhost Help On Line)
.

IN2 is not used in the Standard Application Program but is available for use
with Custom Application Programs.