DS4300

Installation - 2.25

NOTE

The auxiliary serial interface of the slave scanners can be used
in Local Echo communication mode to control any single
scanner (visualize collected data) or to configure it using the
WinHost utility or Host Mode Programming procedure.

The termination resistors of the RS485 bus must not be
installed.

2.6.5 Multiplexer

Each scanner is connected to an MX4000 with the RS485 half duplex mode
on the main interface.

Host

MX4000

0

1

31

1

3

2

3

2

3

2

1

2

3

RS485 HD Main interface

Auxiliary interface (Local Echo)

External Trigger (for On-Line mode)

Figure 2.32 - Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo
communication mode to control any single scanner (visualize collected data)
or to configure it using the WinHost utility or Host Mode Programming
procedure.

When On-Line Operating mode is used, the scanner is activated by an
External Trigger (photoelectric sensor) when the object enters its reading
zone.