Datalogic Scanning LASER SCANNER DS4300 User Manual
Page 21
![background image](/manuals/74845/21/background.png)
DS4300
DATALOGIC
2.6 - Installation
Figure 2.7 - Junction box connector and pinout
To allow connection of an NEC Class 2
Power Unit, use a correct female plug
adapter.
Figure 2.8 - NEC Class 2 Power unit connections
*
The signals on pins 24, 25 and 26 are repeated
on pins 29, 30 and 31 to facilitate network
connections (i.e. Multiplexer connections using
the RS485 half-duplex Interface). In this way the
network bus can enter and exit the junction box
from different spring clamps but be physically
connected together.
Pin
RS232
RS485
full-duplex
RS485
half-duplex
20 mA CL
(INT-24 Only)
24, 29
TX232
TX485+
RTX485+
25, 30
RTS232
TX485-
RTX485-
CLOUT-
26, 31
SGND Main
SGND Main
SGND Main
SGND Main
32
RX232
RX485+
33
CTS232
RX485-
CLIN-
1
17
18
39
J1
5
J. BOX pinout for DS4300
Pin
Name
01
VS
02
GND
03
VS
04
GND
05
CHASSIS
06
VS
07
VS
08
EXT TRIG+
09
EXT TRIG-
10
GND
11
GND
12
VS
13
VS
14
IN1+
15
IN1-
16
GND
17
GND
18
OUT1+
19
OUT1-
20
OUT2+
21
OUT2-
22
IN2+
23
IN2-
*24
Main interface signals
*25
see table below
*26
27
Reserved
28
GND
29
Main interface signals
30
see table below
31
32
33
34
GND
35
TXAUX
36
SGND Aux
37
GND
38
RXAUX
39
Reserved
Junction Box
NEC Class 2
Power supply
Female Plug
System cables