Operation modes supported in each device family, Parameter settings – Altera ALTPLL (Phase-Locked Loop) IP Core User Manual
Page 4
![background image](https://www.manualsdir.com/files/763675/content/doc004.png)
The following list describes the operation modes for the ALTPLL IP core:
• Normal mode—The PLL feedback path source is a global or regional clock network, minimizing clock
delay to registers for that clock type and specific PLL output. You can specify PLL output that is
compensated in normal mode.
• Source-Synchronous mode—The data and clock signals arrive at the same time at the data and clock
input pins. In this mode, the signals are guaranteed to have the same phase relationship at the clock and
data ports of any Input Output Enable register.
• Zero-Delay Buffer mode—The PLL feedback path is confined to the dedicated PLL external clock output
pin. The clock port driven off-chip is phase aligned with the clock input for a minimal delay between the
clock input and the external clock output.
• No Compensation mode—The PLL feedback path is confined to the PLL loop. It has no clock network
or other external source. A PLL in no-compensation mode has no clock network compensation, but clock
jitter is minimized.
• External Feedback mode—The PLL compensates for the
fbin
feedback input to the PLL. The delay
between the input clock pin and the feedback clock pin is minimized.
Operation Modes Supported in Each Device Family
The following table summarizes the operation modes supported for each device family.
Table 2: PLL Types and Modes Supported in Different Device Families
External Feedback
No Compensation
Zero-Delay Buffer
Source-
Synchronous
Normal
Device Family
Enhanced PLL
All PLL types
Enhanced PLL
All PLL types
All PLL types
Arria GX
—
Left_Right PLL
Left_Right PLL
Left_Right PLL
Left_Right PLL
Arria II GX
All PLL types
All PLL types
All PLL types
All PLL types
All PLL types
Stratix IV
Enhanced PLL
All PLL types
Enhanced PLL
All PLL types
All PLL types
Stratix III
Enhanced PLL
All PLL types
Enhanced PLL
All PLL types
All PLL types
Stratix II
Enhanced PLL
All PLL types
Enhanced PLL
All PLL types
All PLL types
Stratix II GX
Enhanced PLL
All PLL types
Enhanced PLL
—
All PLL types
Stratix
Enhanced PLL
All PLL types
Enhanced PLL
—
All PLL types
Stratix GX
—
All PLL types
All PLL types
All PLL types
All PLL types
Cyclone IV
—
All PLL types
All PLL types
All PLL types
All PLL types
Cyclone III
—
All PLL types
All PLL types
All PLL types
All PLL types
Cyclone II
—
All PLL types
All PLL types
—
All PLL types
Cyclone
Parameter Settings
Describes how to set the operation mode for the PLL using the ALTPLL parameter editor. The parameter
settings are located on the General/Modes page of the ALTPLL parameter editor.
ALTPLL (Phase-Locked Loop) IP Core User Guide
Altera Corporation
ug-altpll
Operation Modes Supported in Each Device Family
4
2014.08.18