Troubleshooting – Nexen TL 10 - 15 801570 User Manual
Page 13

10
FORM NO. L-21185-B-1209
TROUBLESHOOTING
FIGURE 12
Ball Seat
(Included in
Drive Flange
Assembly)
Ball
(Included in
Drive Flange
Assembly)
Drive
Flange
Assembly
Backing
Plate
Hub
Ball
Bearings
Drive
Ring
Rotary
Seal
Ball
Bearing
Compression
Spring
O-ring
Seal
Piston
Back-Up
Ring Seal
Ball
Bearing
O-ring
Seal
Back-Up
Ring Seal
SYMPTOM
PROBABLE CAUSE
SOLUTION
Failure to engage
Insufficient air pressure to the Torque Limiter
Check the air line for leaks and replace
damaged air lines.
Damaged or leaking seals
Replace the O-ring Seals.
Failure to Disengage
Broken Compression Springs
Replace the Compression Springs.
Air not exhausting from the Quick Exhaust
Shuttle Valve
Replace the Quick Exhaust Shuttle Valve.
Ratcheting
Insufficient air pressure to the Torque Limiter
Check the air lines for leaks and replace
damaged air lines.
Damaged or leaking O-ring Seals.
Replace the O-ring Seals.
Nuisance Tripping
Limit Switch not properly adjusted
Adjust the Limit Switch (See
ADJUSTMENTS section.)