beautypg.com

Nexen TL 10 - 15 801570 User Manual

Page 12

background image

9

FORM NO. L-21185-B-1209

OPERATION

WARNING

Never exceed maximum operating speeds
listed for your product (See Table 4).

The temperature limits for this product line
are 4.5º - 104º C (40º-220º F).

CAUTION

CAUTION

The balls will not find the detents without
sufficient resistance of the Drive Flange
downstream to prevent it from rotating.

TABLE 4 Maximum Allowable Speed

Model

Maximum Operating Speeds

TL20-A, TL20-AC

1800 RPM

TL30-A, TL30-AC

1650 RPM

TL40-A, TL40-AC

1350 RPM

TL50-A, TL50-AC

1200 RPM

TL60-A, TL60-AC

1050 RPM

TL70-A, TL70-AC

950 RPM

TL80-A, TL80-AC

800 RPM

RE-SETTING PROCEDURE

1. Shut down the machine drive.

2. Apply air pressure to the Torque Limiter.

3. Rotate Drive Flange Assembly by hand or in "jog"

mode until the balls are engaged in the detents.

INTERFACE DESIGN

The Torque Limiter interface consists of opposing balls and
detents that are not equally spaced and engage in one rota-
tional position. This feature provides exact timing or registry
of machine components connected on the drive and driven
side of the Torque Limiter. If an overload occurs, the torque
limiter interfaces separate to completely disconnect drive
components from driven components.

4. Restart the machine drive.

NOTE

Machine must come to a complete stop before

Torque Limiter can be reengaged. Torque Limiter

may run in excess of 200

o

F [93°C] as measured

on the Air Chamber until Rotary Seal has worn in.

This manual is related to the following products: