Nexen TL 10 - 15 801570 User Manual
Page 12

9
FORM NO. L-21185-B-1209
OPERATION
WARNING
Never exceed maximum operating speeds
listed for your product (See Table 4).
The temperature limits for this product line
are 4.5º - 104º C (40º-220º F).
CAUTION
CAUTION
The balls will not find the detents without
sufficient resistance of the Drive Flange
downstream to prevent it from rotating.
TABLE 4 Maximum Allowable Speed
Model
Maximum Operating Speeds
TL20-A, TL20-AC
1800 RPM
TL30-A, TL30-AC
1650 RPM
TL40-A, TL40-AC
1350 RPM
TL50-A, TL50-AC
1200 RPM
TL60-A, TL60-AC
1050 RPM
TL70-A, TL70-AC
950 RPM
TL80-A, TL80-AC
800 RPM
RE-SETTING PROCEDURE
1. Shut down the machine drive.
2. Apply air pressure to the Torque Limiter.
3. Rotate Drive Flange Assembly by hand or in "jog"
mode until the balls are engaged in the detents.
INTERFACE DESIGN
The Torque Limiter interface consists of opposing balls and
detents that are not equally spaced and engage in one rota-
tional position. This feature provides exact timing or registry
of machine components connected on the drive and driven
side of the Torque Limiter. If an overload occurs, the torque
limiter interfaces separate to completely disconnect drive
components from driven components.
4. Restart the machine drive.
NOTE
Machine must come to a complete stop before
Torque Limiter can be reengaged. Torque Limiter
may run in excess of 200
o
F [93°C] as measured
on the Air Chamber until Rotary Seal has worn in.