Pilz PSSnet SHL 8T MRP User Manual
Page 33

Ring/Network coupling
PSSnet SHL - Redundancy Configuration
Pilz GmbH & Co. KG, Felix- Wankel Str. 2, 73760 Ostfildern
3.2 Preparing a Ring/Network cou-
pling
33
Note: Configure the partner coupling port and the HIPER-Ring ports on
different ports.
Select the coupling port
(see fig.
10)
,
(see table
7)
.
With “Coupling port” you specify at which port you are connecting
the redundant line.
Note: Configure the coupling port and the redundancy ring ports on
different ports.
Activate the function in the “Operation” frame
(see fig.
16)
.
You now connect the redundant line.
The displays in the “Select port” frame mean
(see fig.
10)
:
– “Port mode”: The port is either active or in stand-by mode.
– “Port state”: The port is either connected or not connected.
The displays in the “Information” frame mean
(see fig.
10)
:
– “Redundancy existing”: One of the lines affected can fail, as a
redundant line will then take over the function of the failed line.
– “Configuration failure”: The function is incomplete or incorrectly
configured.
Figure 10: Selecting the port and enabling/disabling operation