beautypg.com

Vortech H3 I-5 Hummer - 2006-2008 User Manual

Page 24

background image

P/N: 4GN020-010

©2008 Vortech Engineering, LLC

All Rights Reserved, Intl. Copr. Secured

20OCT08 v2.0(4GNv2.0)

16

Fig. 8-a

Fig. 8-b

Fig. 8-c

8. AIR INLET INSTALLATION

A. Locate the MAF mounting hole template in

this manual. Remove and cut the template as

shown. Place the template on the passenger

side inner fender and mark the three hole

positions to be drilled. Drill the previously

marked hole locations using a 1/4" drill.

B. Install the MAF meter into the air filter cover.

Place the supplied air filter on to the meter

and secure. (See Fig. 8-a.)

C. 2007 Models Only Locate the evaporative

canister air horn and vent filter bulkhead con-

nector removed in a previous step. Install the

bulkhead connector and air horn into the sup-

plied air filter cover. (See Fig. 8-b.)

D. 2008 Models Only: Locate the

Ø1” x 1.13” x 2.25” long union. Install the

union into the air filter cover using the sup-

plied rubber grommet. Attrach the supplied

Ø1-1/8” filter to the previously installed union

and secure

E.

Install the air filter assembly into the vehicle.

Secure the MAF meter to the previously

drilled holes in the inner fender using the 1/4-

20 hardware provided. (See Figure 8-d.)

F. Secure the forward edge of the air filter hous-

ing to the front core support using the sup-

plied 90° bracket, 1/4-20 hardware and M6

Nyloc nut. Connect the previously installed

water pump ground wire to the core support

at this trime.(See Fig. 8-c.)

G. Install the previously removed MAF electron-

ics into the supplied meter housing and

secure using the supplied hardware.

Connect the MAF electronics harness to the

MAF. (See Figure 8-d)

H. Locate the previously removed evaporative

canister vent hose. Connect the 45° fitting to

the vent filter bulkhead connector previously

installed in the supplied air filter cover.

Connect the 90° elbow to the port on the

evaporative canister. (See Fig. 8-c.)

I.

2008 Models Only: Locate the previously

removed evaporative canister vent hose.

Connect the 45° fitting to the port on the

evaporative canister. Remove the factory 90°

fitting for the opposite end of the hose and

discard. Connect the open end of the hose to

the union previously installed in the supplied

air filter cover.

MAF METER

AIR FILTER

FILTER

COVER

NOTE:

Install one tab on the bulkhead connector

first and then twist to allow the remaining

tabs to pop into place.

90° BRACKET