Test Products International 460 User Manual
Page 9
Optional Adapter 3
A296 (AC/DC AMPS)
Range
0 - 400A / 400 - 1000A
Accuracy ( 0 - 400A )
+/- (2.0% + 10 digits , 50 / 60 Hz)
(400 - 1000A)
+/- (2.0% + 10 digits , 50 / 60 Hz)
MULTIMETER MODES
DC Volts (CH1/CH2)
Range
Resolution
Accuracy
400mV
0.1mV
+/- (0.5% + 5 digits)
4V
0.001V
+/- (0.5% + 5 digits)
40V
0.01V
+/- (0.5% + 5 digits)
400V
0.1V
+/- (0.5% + 5 digits)
600V
1V
+/- (0.5% + 5 digits)
AC Volts (CH1/CH2)
Range
Resolution
Accuracy
400mV
0.1mV
20Hz to 50Hz; +/- (2% + 20 digits)
4V
0.001V
50Hz to 1kHz; +/- (1% + 10 digits)
40V
0.01V
1kHz to 20kHz; +/- ( 2% + 10 digits)
400V
0.1V
40Hz to 400Hz; +/- (1% + 10 digits)
600V
1V
40Hz to 400Hz; +/- (1% + 10 digits)
Frequency (CH1/CH2)
Range
Resolution
Accuracy
100Hz
0.01Hz
+/- (1.0% + 10 digits)
1KHz
0.1Hz
+/- (0.5% + 5 digits)
10KHz
1Hz
+/- (0.5% + 5 digits)
100KHz
10Hz
+/- (0.5% + 5 digits)
1MHz
100Hz
+/- (0.5% + 5 digits)
10MHz
1kHz
+/- (0.5% + 5 digits)
20MHz
10kHz
+/- (2.5% + 5 digits)
OHM (CH1 ONLY)
Range
Resolution
Accuracy
400 Ohm
0.1 Ohm
+/- (0.75% + 5 digits)
4k Ohm
1 Ohm
+/- (0.5% + 5 digits)
40k Ohm
10 Ohm
+/- (0.5% + 5 digits)
400k Ohm
100 Ohm
+/- (0.5% + 5 digits)
4M Ohm
1k Ohm
+/- (1.0% + 10 digits)
20M Ohm
10k Ohm
+/- (3.0% + 20 digits)
460 User s Guide
Introduction
C1-5