Specifications – Test Products International 460 User Manual
Page 7

o
A254 - For measuring low current in milliamps
o
A256 - Up to 400 AC/DC amps
o
A296 - Up to 1000 AC/DC amps
Specifications
Display:
Size
76mm X 76mm (3" X 3")
Pixels
240 X 240 pixels
LCD type
STN Normally Gray or Black
Back Light
CCFL
Memory:
Waveform Screens
(2)
Setup
User setup (1)
Power:
External
Power Adapter (5.5V / 2A)
Internal Battery
Ni-MH 1.2V X 4
Battery Operating Time
More than 2.5 hours with bright backlight
Charging Time
10 hours (in power off condition)
SCOPE MODES
Horizontal:
Samples per division
25 samples / div.
Time/division
Equivalent sampling 50ns to 500ns/div
Real time sampling 1us to 2s/div
Modes
Single, Normal, Auto, Glitch
Accuracy
Real time sampling +/- (0.1% + 0.04 time/div)
Equivalent sampling +/- (0.5% + 0.08 time/div)
Vertical:
Sampling Rate
25 Mega samples per second
Bandwidth (-3dB)
DC Coupled
1:1 shielded test leads ; DC to 10MHz
Coaxial cable (50Ω)
; DC to 20MHz
AC Coupled
1:1 shielded test leads ; 10Hz to 10MHz
Coaxial cable (50Ω)
; 10Hz to 20MHz
Resolution
8 bits
Channel
2
Coupling
AC,DC,GND
460 User s Guide
Introduction
C1-3