beautypg.com

SOR 1510 Side Mounted Level Switch User Manual

Page 3

background image

Form 451 (11.13) ©SOR Inc.

3/8

Linear = mm/inches

Drawing 0390747

APPLY TWO DROPS

LOCTITE 271 INSIDE

THREADED HOLE

OF FLOAT

FLOAT

SET SCREW

Place two drops of Loctite 271

inside the threaded hole of the float.

Thread the float onto the set

screw and hand-tighten.

NOTE: Do not remove the set screw as
it secures the pivot arm to the shaft.

Float Attachment (Series 1500 with Flange)

Safety Integrity Level (SIL) Installation Requirements

The SOR pressure switches have been evaluated as Type-A safety related hardware.
To meet the necessary installation requirements for the SIL system, the following
information must be utilized:

„ Proof Test Interval shall be one year.
„ Units may only be installed for use in Low Demand Mode.
„ Products have a HFT (Hardware Fault Tolerance) of 0, and were evaluated in a

1oo1 (one out of one) configuration.

Form 1538 (03.12) ©2012 SOR Inc.