Dimensions

Linear = mm/inches

Drawing 0091119

Wiring 534HS-VN

Three screw terminals and center ground are provided for electrical connection,
labeled as follows:

+

11-30 VDC + Power Connection

Power supply ground

1-5 VDC Output

GND

Case ground should be connected to earth ground.

Formula for determining

maximum loop resistance:

R

L

(Max) =

V

Supply

- 16V

Dimensions are for reference only.