7 safety devices, 5 chemical and biological safety, 1 system check – Martin Christ Gamma 2-16 LSCplus User Manual
Page 27: 2 earth conductor check
![background image](/manuals/739283/27/background.png)
Gamma 1-16 LSC&
Gamma 2-16 LSC&
3 Safety
Version 04/2013, Rev. 1.1 of 16/12/2013 • sb
27
Translation of the original operating manual
Pos: 66 / 200 Christ /36 0 GT -BA La bor -Pilot (S TANDARDMODULE) /03 0 Sicher heit/ 030 -00 60- 005 0 Ch emisc he u nd biologisc he Sich erh eit @ 5\m od_1 299 136 465 291 _68. docx @ 34 748 @ 3 @ 1
3.6.5 Chemical and biological safety
If infectious, toxic, pathogenic, or radioactive substances are intended to be
dried, it is in the responsibility of the user to ensure that all necessary
safety regulations, guidelines, precautions, and practices are adhered to
accordingly.
DANGER
• Infectious, toxic, pathogenic, and radioactive substances must be dried
in suitable accessories. Take suitable precautions for your own safety!
• Do not dry products with a high solvent concentration or acidic
products without special protective measures or device-based
precautions (e.g. an additional cooling trap to protect the vacuum
pump). It is absolutely necessary to consult the manufacturer in these
cases (see chapter 7.3 - "Service contact").
• Special caution is necessary when handling azides, as a dangerous
explosive develops in combination with copper or nonferrous metals! It
is absolutely necessary to contact the manufacturer (see chapter 7.3 -
"Service contact").
WARNING
• Keep informed about local measures to avoid harmful emissions
(depending on the substances to be dried).
• As personal protective equipment, safety gloves are required for the
use of the freeze-dryer.
The materials to be dried may, however, require additional special
safety measures (e.g. drying of infectious, toxic, radioactive, or
pathogenic substances)
Pos: 67 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1
Pos: 68 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1
Pos: 69 / 200 Christ /36 0 GT -BA La bor -Pilot (S TANDARDMODULE) /03 0 Sicher heit/ 030 -00 70 Sic her heitsei nricht ung en- -- --- -- --- --- -- --- -- --- -- --- --- -- --- -- --- --- -- --- -- -- @ 6\m od_ 129 913 646 611 9_68 .docx @ 3 476 4 @ 2 @ 1
3.7 Safety devices
Pos: 70 / 200 Christ /36 0 GT -BA La bor -Pilot (S TANDARDMODULE) /03 0 Sicher heit/ 030 -00 70- 001 0 Syst emko ntr olle @ 6\m od_1 299 136 466 494 _68. docx @ 34 772 @ 3 @ 1
3.7.1 System check
An internal system check system monitors the data transfer and sensor
signals with regard to plausibility. Errors are detected by continuous self-
monitoring of the system. Error messages are displayed in the main
window under "Process & equipment messages" (chapter 6.5.1.1 - "Main
window "Manual"", chapter 7.2 - "Process and error messages").
Pos: 71 / 010 Unive rsalm odul e/ L ee rzeile @ 0\ mod _120 211 624 450 0_0. docx @ 11 4 @ @ 1
Pos: 72 / 200 Christ /36 0 GT -BA La bor -Pilot (S TANDARDMODULE) /03 0 Sicher heit/ 030 -00 70- 002 0 Sch utzleite rp rüfu ng Alph a - Ga mma @ 6\ mod _12 991 364 669 00_ 68.d ocx @ 347 80 @ 3 @ 1
3.7.2 Earth conductor check
For the earth conductor check, there is an equipotential bonding screw on
the rear panel of the freeze-dryer. An earth conductor check can be carried
out with the aid of a suitable measuring instrument.
Pos: 73 / 010 Unive rsalm odul e/ Seit enwec hsel @ 0\m od_ 120 211 6244 312 _0. docx @ 10 5 @ @ 1