Hall Research URA-232-XT User Manual
Page 25
PC (VGA) & HD (YPbPr) AV with RS232 over Twisted-Pair Receivers
23
4.13 RS-232 Command Summary
The URA-232 consists of the following serial commands.
The unit communicates at 19200, No Parity, 8 Data Bits, 1 Stop Bit
To use the commands listed below, the unit must be in Adjustment-mode.
• Apply power to the receiver. Wait until all LED’s are turned off
• Press the SEL button once to enter Adjustment-mode.
• In Adjustment-mode, all three (3) LEDs will be turned ON.
• Send the RS-232 Serial command at 19200 baud, No parity, 8 Databits, 1
Stop bit, to get into the programming mode(e.g) Pass_Word
• All three (3) LED’s should be blinking and the device will have replied serially
with three (3) characters. ACK (0x06), CR (0x0D) and LF (0x0A).
• Once in this mode, the commands listed below may be used.
• Send the RS-232 Serial command EXIT
return to Adjustment-mode.
COMMAND
FUNCTION
VER?
Read firmware version – UNIT responds with “Ver x.y
IO?
IO0
IO1
Query discrete input type – UNIT responds with “IO1” or “IO0”
Set discrete input type to Contact Closure
Set discrete input type to Voltage (5-30 vDC)
FDFT
Factory default – UNIT responds with “Are you sure (Y,N)?”, a “Y
response. Any other response to the question or failure to answer with in 8 seconds will result in a “Cancelled”
response.
NO CONTACT Closure is the factory default.
RSTU
Unit reset – UNIT will respond with “Reset URA
Pass_Word
Password to get into the programming mode
EXIT
Exit the programming mode and back to the adjustment mode
RESERVED COMMANDS
Re
RESERVED FOR HALL RESEARCH
RE
RESERVED FOR HALL RESEARCH
We
RESERVED FOR HALL RESEARCH
WE
RESERVED FOR HALL RESEARCH
RST0
RST1
RST2
RST3
Reset Video Compensation to 0
Reset RED Skew to 0
Reset GREEN Skew to 0
Reset BLUE Skew to 0
INC0
INC1
INC2
INC3
Increment Video Compensation by 1
Increment RED Skew Correction by 1
Increment GREEN Skew Correction by 1
Increment BLUE Skew Correction by 1
DEC0
DEC1
DEC2
DEC3
Decrement Video Compensation by 1
Decrement RED Skew Correction by 1
Decrement GREEN Skew Correction by 1
Decrement BLUE Skew Correction by 1
RD0? Or RD0
RD1? Or RD1
RD2? Or RD2
RD3? Or RD3
Read HF Compensation & Gain Settings
UNIT responds with “x, y
Read Skew Correction Values (RGB)
UNIT responds with “R, G, B
RDUS
Read Unit Settings
WG?
WG1
WG0
Query Wire Gauge setting – UNIT responds with “23G” or “24G”
Set 24 AWG wire size
Set 23 AWG wire size