PC (VGA) & HD (YPbPr) AV with RS232 over Twisted-Pair Receivers

23

4.13 RS-232 Command Summary

The URA-232 consists of the following serial commands.
The unit communicates at 19200, No Parity, 8 Data Bits, 1 Stop Bit

To use the commands listed below, the unit must be in Adjustment-mode.

• Apply power to the receiver. Wait until all LED’s are turned off

• Press the SEL button once to enter Adjustment-mode.

• In Adjustment-mode, all three (3) LEDs will be turned ON.

• Send the RS-232 Serial command at 19200 baud, No parity, 8 Databits, 1

Stop bit, to get into the programming mode(e.g) Pass_Word

• All three (3) LED’s should be blinking and the device will have replied serially

with three (3) characters. ACK (0x06), CR (0x0D) and LF (0x0A).

• Once in this mode, the commands listed below may be used.

• Send the RS-232 Serial command EXIT to exit programming mode and

return to Adjustment-mode.

COMMAND

FUNCTION

VER?

Read firmware version – UNIT responds with “Ver x.y” where x.y are the major and minor version numbers.

IO?
IO0
IO1

Query discrete input type – UNIT responds with “IO1” or “IO0”
Set discrete input type to Contact Closure
Set discrete input type to Voltage (5-30 vDC)

FDFT

Factory default – UNIT responds with “Are you sure (Y,N)?”, a “Y” response will result in a “Factory Defaults”
response. Any other response to the question or failure to answer with in 8 seconds will result in a “Cancelled”
response.
NO CONTACT Closure is the factory default.

RSTU

Unit reset – UNIT will respond with “Reset URA

Pass_Word

Password to get into the programming mode

EXIT

Exit the programming mode and back to the adjustment mode

RESERVED COMMANDS

Re

RESERVED FOR HALL RESEARCH

RE

RESERVED FOR HALL RESEARCH

We

RESERVED FOR HALL RESEARCH

WE

RESERVED FOR HALL RESEARCH

RST0
RST1
RST2
RST3

Reset Video Compensation to 0
Reset RED Skew to 0
Reset GREEN Skew to 0
Reset BLUE Skew to 0

INC0
INC1
INC2
INC3

Increment Video Compensation by 1
Increment RED Skew Correction by 1
Increment GREEN Skew Correction by 1
Increment BLUE Skew Correction by 1

DEC0
DEC1
DEC2
DEC3

Decrement Video Compensation by 1
Decrement RED Skew Correction by 1
Decrement GREEN Skew Correction by 1
Decrement BLUE Skew Correction by 1

RD0? Or RD0

RD1? Or RD1
RD2? Or RD2
RD3? Or RD3

Read HF Compensation & Gain Settings
UNIT responds with “x, y
Read Skew Correction Values (RGB)
UNIT responds with “R, G, B

RDUS

Read Unit Settings

WG?
WG1
WG0

Query Wire Gauge setting – UNIT responds with “23G” or “24G”
Set 24 AWG wire size
Set 23 AWG wire size

This manual is related to the following products: