beautypg.com

10 settings tab – Hall Research URA-232-XT User Manual

Page 22

background image

Model URA-232 & URA-232-XT

20

4.10 Settings Tab

• The Settings tab allows the user to configure the discrete input mode and serial

mode of operation. Refer to figure 4-6 below.

• The discrete input is configurable as a contact closure, a voltage input, or not

used at all.

The serial mode can be configured as pass-thru, remote button trigger or
remote command trigger

Discrete Input Table

High

Low

Discrete Input

Level

Condition

Level

Condition

Contact closure

Open

Discrete Input High

Closed

Discrete Input Low

Voltage

5V-30V

Discrete Input High

0V

Discrete Input Low


NOTE: If a discrete input is not used in the Pass-thru mode, the URA-232 unit will go
into a power-conserving mode when there is no front panel activity or no
communication with URA-232 Programmer

Remote Trigger Table

High

Low

Remote Trigger

Input

Condition

Input

Condition

Button

UV232A-xS

Green LED

Remote Trigger On

UV232A-xS

Red LED

Remote Trigger Off

Serial Command

TR1

Remote Trigger On

TR0

Remote Trigger Off

In “PASS-THRU MODE”, any serial data received on the CATx cable is sent out the 3-pin
serial terminal block without modification. The URA-232 does not monitor the serial
information.

In “REMOTE BUTTON TRIGGER MODE”, the URA-232 unit will monitor the CATx input
signal from the sending unit.
o

Pressing the button on the sending unit will send the user configuration string for
“REMOTE TRIGGER ON”, and pressing the button again will send a user
configuration string for “REMOTE TRIGGER OFF”.

In “REMOTE TRIGGER COMMAND MODE”, the URA-232 unit will monitor the incoming
SENDER serial commands for TR1 or TR0 at a baud rate of 19200, 8-bit data, no
parity, and 1-stop bit.
o

If detected, it will process the user configuration string for “REMOTE TRIGGER ON” or
“REMOTE TRIGGER OFF” accordingly

o

Sending any other commands to the unit will cause the 3 LED’s (RGB) to blink 2 times
to indicate an error condition.

o

The URA-232 indicates its serial mode at power-up as listed below:

Serial Mode

LEDs Blink

Pass-Thru None
Remote Button Trigger

2 times

Remote Command Trigger

4 times

This manual is related to the following products: