MAINTENANCE

- 37 -

DIAGNOSTIC CODES - LEVEL 1

Installer Access

14602

To enter the diagnostics menu follow the procedure below:-

Press and hold the ‘MODE’ and ‘+’ buttons for approx.... 5 seconds until the screen changes. Use the ‘+’ or ‘-’ button to select the

number 96, this is the password. Hold the ‘MODE’ for approx.... 5 seconds when 96 is selected, when the screen changes release the

button. The screen will flash between ‘L1’ and a number. ‘L1’ indicates you have level 1 access, the number indicates the diagnostic

number below. Use the ‘+’ and ‘-’ to cycle through the selections below. To select a diagnostic number press the ‘MODE’ button when

the correct number is selected. The display will show the parameter value of the diagnostic number selected. To return to the diagnostic

number selector simply press the ‘MODE’ button. To change the parameter use the + or - buttons. Once the value has been changed it

must be saved by holding the ‘MODE’ button for approximately 5 seconds. This will return to the diagnostic number selector.

Diagram 13.6

d.99 State list

(see State Lists table)

d.28 Option relay 2

reserved for future use

d.27 Option relay 1

reserved for future use

d.24 Water pressure

in bar

d.97 Activation of second diagnostic level Password needed

>8 no flame, <4 good flame

Indicates read and write function - all other diagnostics are read only