10 Electrical Connection
WARNING:
This appliance must be earthed.
● This appliance must be wired in accordance with these 
instructions. Any fault arising from incorrect wiring cannot be 
put right under the terms of the Glow-worm guarantee.
● All system components must be of an approved type.
Electrical components have been tested to meet the equivalent 
requirements of the BEAB.
● Do not interrupt the mains supply with a time switch or 
programmer.
● Connection of the whole electrical system and any heating 
system controls to the electrical supply must be through a 
common isolator.
● Isolation should preferably be by a double pole switched 
fused spur box having a minimum contact separation of 3mm 
on each pole. The fused spur box should be readily accessible 
and preferably adjacent to the boiler. It should be identifi ed as 
to its use.
● A fused three pin plug and shuttered socket outlet may be 
used instead of a fused spur box provided that it is not used in a 
room containing a fi xed bath or shower.
● The boiler is suitable for installation in bathroom zones 2 and 
3.
10.1 Electrical Wiring
Remove the electrical cartridge from the fi ttings pack.
Remove the securing screw to open the cartridge, see diagram 
10.1.
NOTE: There are two screws supplied loose in the electrical 
cartridge, these will be required to secure the cartridge into the 
electrical interface housing.
Slacken the cable strain relief screws in the electrical cartridge, 
see diagram 10.1.
Route the mains supply and system cables through the strain 
relief and connect to the relevant plug, see diagram 10.2.
10.2 Pump Wiring
Ensure that a seperate pump supply cable is routed through the 
strain relief and connected to the relevant plug, see diagram 
10.2.
Slacken the cable strain relief and route the pump electrical 
supply cable and connect as shown in diagrams 10.1 and 10.2.
Diagram 10.1
13905
Diagram 10.2
13457