Installation – Glow-worm Climapro2 RF User Manual
Page 13
![background image](/manuals/736755/13/background.png)
0020094586_01 - 08/10 - Glow-worm
- 11 -
INSTALLATION
10.2 Access to the installer menu
• Press button
for 7 seconds.
• Enter the installer code 96.
10.3 Description of the installer menu
Menu
browsing
Use the buttons:
Select with the button:
Select with the button:
-
to return to the professional menu
screen,
-
for 3 seconds to return to the user's
main screen.
Showing, enabling and disabling of functions is
reflected in the user menu.
10.4 heating function
Menu
This menu lets you:
Set the maximum adjustable room
temperature.
Correct the measurement of the room
temperature.
Activate or deactivate the modulating
control for the hot water temperature.
(*) automatic adjustment of the heating water temperature
10.4.1
To set the maximum room temperature
This function lets you adjust the maximum room temperature
that can be set by the user (value adjustable between 5 and
30 °C - factory setting: 30 °C).
• From the installer menu (see access to the installer menu) >
select on the screen >
heating > maximum room T
O
.
• Increase or decrease with the buttons
to display the
initial cooling temperature and press the button
.
10.4.2
Correcting the room temperature
This function lets you rectify the temperature measured by the
ambient temperature thermostat (by +/- 5 °C with a step of
0.5 °C - (factory setting : 0).
• From the installer menu (see access to the installer menu)
> select on the screen >
heating > room temperature
correction
• Increase or reduce with the
buttons to display the
desired correction and validate with button
.
10.4.3
Activating or deactivating the modulating
control
This function lets you adapt the flow temperature in the heating
system.