Installation – Glow-worm Climapro2 RF User Manual
Page 11
0020094586_01 - 08/10 - Glow-worm
- 9 -
INSTALLATION
Case n°2 - radio receiver in the control box unit
A
RT 24V
T° ext
BUS
BUS
24 V
B
1
2
3
5
4
Legend
1 ebUS connecting cable
2 Link for the connection terminal block on the room thermostat
3 ebUS terminal block for the main board
4 Control box unit
5 Radio receiver connector
• Do not remove the link from the terminal block (2) connecting
the room thermostat to the main board.
• Connect (A and B) the EBUS cable (1) to the radio receiver's
connector (5) and to the EBUS terminal block on the main
board (3). There is no polarity that must be respected.
Case n°3 - radio receiver outside the appliance
1
2
3
Legend
1 ebus and 0V connection
2 Cable strain relief
3 Connector for the radio receiver
• Do not remove the link from the terminal block for connecting
the main board’s room thermostat.
• Connect the EBUS cable to the radio receiver connector
and the EBUS and 0V connection in the electrical cartridge.
Polarity is not important.
8.3
Pairing (recognition)
8.3.1
The room thermostat delivered with a radio
receiver
The pairing between the room thermostat and its radio receiver
requires no action on your part. It is carried out in the factory.
8.3.2
The radio receiver with wireless outdoor
sensor
Pairing between the external temperature probe and the radio
receiver is possible (see the installation manual for the external
probe).
The radio receiver can be paired with the wireless outdoor
sensor (see the outdoor sensor installation manual).