beautypg.com

A technical specifications, Mportant, Optical switch – EXFO IQS-9100 Optical Switch for IQS-500/600 User Manual

Page 71

background image

Optical Switch

65

A Technical Specifications

I

MPORTANT

The following technical specifications can change without notice.
The information presented in this section is provided as a reference
only. To obtain this product’s most recent technical specifications,
visit the EXFO Web site at www.exfo.com
.

Model

1x2

1x4, 1x8, 1x12, 1x16, 1x24, 1x32, 2x4

f

2x2

Mode

Singlemode

Multimode

Singlemode

Multimode

Singlemode

Multimode

Insertion loss

b

(dB)

typical

0.5

0.5

0.7

0.5

0.8

0.5

maximum

1.5

1.5

1.7

1.7

1.5

1.5

Backreflection

c

(dB)

maximum

–55

–24

–55

–24

–55

–24

Repeatability

d

(dB)

maximum

± 0.01

± 0.01

± 0.03

± 0.03

± 0.01

± 0.01

Operating wavelengths (nm)

1290 to 1570

780 to 1350

1290 to 1650

780 to 1350

1290 to 1570

780 to 1350

Polarization-dependent loss

e

(dB)

typical

) 0.05

-

) 0.05

-

) 0.05

-

standard maximum

0.10

-

0.10

-

0.10

-

on request maximum

0.05

-

0.05

-

0.05

-

Maximum input power (dBm)

+24

+24

+24

+24

+24

+24

Switching time (ms)

25

25

25 per channel + 425 (debouncing)

25

25

Number of channels

1x2

1x2

1x4, 1x8, 1x12, 1x16, 1x24, 1x32

2x2

2x2

Crosstalk (dB)

–80

–80

–80

–80

–80

–80

NOTES

a. Specifications valid at 23 °C ± 5 °C.

b. Insertion loss per module, excluding connectors, measured at singlemode wavelengths of 1310 nm and 1550 nm,

and multimode wavelength of 850 nm.

c. Backreflection is measured at singlemode wavelengths of 1310 nm and 1550 nm, with APC connectors,

and multimode wavelength of 850 nm.

d. Repeatability values are for 100 cycles per switch module at constant temperature with stabilized source/meter

at singlemode wavelengths of 1310 nm and 1550 nm, and multimode wavelengths of 850 nm and 1300 nm.

e. Measured at 1550 nm. Lower polarization-dependent loss is available upon request.

f. Non-blocking.

,

,

Number of slots

1

1

2

h

3

a

5

1

2

b

Dimensions

Width

3.6 cm (1

7

16

in)

3.6 cm (1

7

16

in)

7.4 cm (2

15

16

in)

11.2 cm (4

7

16

in)

18.8 cm (7

7

16

in)

3.6 cm (1

7

16

in)

7.4 cm (2

15

16

in)

Height

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

12.5 cm (4

15

16

in)

Depth

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

28.2 cm (11

1

8

in)

Weight

0.5 kg (1.1 lb)

0.8 kg (1.8 lb)

0.9 kg (2.0 lb)

0.9 kg (2.0 lb)

1.4 kg (3.2 lb)

0.5 kg (1.1 lb)

1.0 kg (2.3 lb)

Switch life

10 million cycles minimum

Temperature

operating

10 °C to 40 °C

(50 °F to 104 °F)

storage

—20 °C to 60 °C

(—4 °F to 140 °F)

Relative humidity maximum

80 % non-condensing at 40 °C

Instruments Drivers

LabVIEW™ drivers, SCPI commands and COM/DCOM librairies

Remote Control

With IQS-500: GPIB (IEEE-488.1, IEEE-488.2) Ethernet and RS-232

Standards Accessories

User Guide and Certificate of Compliance

NOTES

a. 2 slots for MU/UPC connectors

b. 1 slot for MU/UPC connectors

c. 2xN configurations available only with 2- and 4-channel options.

d. Singlemode only.

e. Multimode only.

f. Available on 1x2, 1x4, 1x8, 1x12, 1x24, 2x2 and 2x4 switches.

g Available for singlemode units. Not with FC/APC, SC/APC or MU/UPC connectors.

h. 1x12 switches w/ EUI connectors use 3 slots.