beautypg.com

Refer ence man ual, Wir eless fuzzyscan, Operation control – Cino L780BT HC User Manual

Page 64

background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

57

PROGRAM

Operation Control

Out-of-range Scanning, Sleep Time-out Control

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

Out-of-range Scanning

SS
SS

Disable
Enable

0
1

Link Supervision Time-out

SS
SS
SS
SS
SS

1 sec
3 secs
5 secs
7 secs
9 secs
Only available in PAIR & PICO modes

0
1
2
3
4

Sleep Time-out of Connect State

SS

MS

6 (x5) minutes
0-99 (x5) minutes



If you don’t want the scanner to enter sleep mode, please set time-out to “0

FIN

(2 digits)

Sleep Time-out of Disconnect State

SS

MS

1 minute
0-99 minutes



If you don’t want the scanner to enter sleep mode, please set time-out to “0

FIN

(2 digits)

Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode
data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to
continue scanning barcode data into memory buffer until radio link resumed.

The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds.

The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically
enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”.