Refer ence man ual, Wir eless fuzzyscan, Symbology reading control – Cino L780BT HC User Manual
Page 33
W
ir
eless FuzzyScan
R
efer
ence Man
ual
Configure Your FuzzyScan
26
PROGRAM
Symbology Reading Control
♦ UPC-A & UPC-E Setting ♦
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
UPC Family Setting
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
Disable UPC-A
Enable UPC-A
Disable UPC-E
Enable UPC-E
Disable UPC-E expansion
Enable UPC-E expansion
Disable UPC standardization
Enable UPC standardization
Disable UPC numeric system
Enable UPC numeric system
Disable UPC-A check digit transmission
Enable UPC-A check digit transmission
Disable UPC-E check digit transmission
Enable UPC-E check digit transmission
Disable UPC “leading 1” portion
Enable UPC “leading 1” portion
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric
system, UPC-A check digit transmission.
UPC-E & EAN-8 Expansion
: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.
UPC-A/E Standardization
: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.
UPC Lead 1 Numeric System
: Enable to read UPC leading with the 1 numeric system, you must enable this option.
WPC Selection
(UPC/EAN/CAN)
Basic Length
Disable
Check Digit
Disable
Numeric System
With 2-digit
Addendum
With 5-digit
Addendum
Enable
Standardization
Enable
Expansion
UPC-A
12
- 1
- 1
+ 2
+ 5
+ 1
0
UPC-E
8
- 1
- 1
+ 2
+ 5
+ 1
+ 4
EAN-13
13
- 1
NC
+ 2
+ 5
NC
0
EAN-8
8
- 1
NC
+ 2
+ 5
NC
+ 5