beautypg.com

Refer ence man ual, Wir eless fuzzyscan, Serial interface control – Cino L780BT HC User Manual

Page 51

background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

44

PROGRAM

Serial Interface Control

Record Suffix, Preamble ,Postamble Setting

F_DEFAULT

Family Code Selection

P.C

Parameter Selection

Option Code

STX/ETX Control

SS
SS

Disable STX/ETX transmission
Enable STX/ETX transmission
STX/ETX are two characters used to indicate the starting and ending of the total
data frame transmitted via serial interface.

0
1

Record Suffix

SS
SS
SS
SS
SS
SS

MS

None
CR (0DH)
LF (0AH)
CRLF (0D0AH)
TAB (09H)
SPACE (20H)
User defined character (1 character)

0
1
2
3
4
5

6, (00-7F)

Preamble

SS

MS

None
1-15 characters

Maximum 15-character input; scan “FIN” to terminate this selection.

FIN

[00-7F], [FIN]

Postamble

SS

MS

None
1-15 characters

Maximum 15-character input; scan “FIN” to terminate this selection.

FIN

[00-7F], [FIN]

Serial Interface Message String (RS232, USB COM) :

STX

Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble ETX Record

Suffix

1 character

1-15 characters

2-3 digits

1 or 2 characters

Variable length

1 or 2 characters 1-15 characters

1 character

1 character

This manual is related to the following products: