Troubleshooting and maintenance, Troubleshooting – AMT Datasouth Fastmark 400 User Manual
Page 44

User's Guide 43
TROUBLESHOOTING AND MAINTENANCE
Troubleshooting
Generally, when a malfunction or an abnormal condition occurs, the “POWER” LED will keep
blinking. Printing and communication between the host and printer will stop.
Power and Ready LEDs blink together at the same time
Possible Problems Solutions
Remarks
Missing gap
Check the media path
Check the paper sensor
If using continuous media with
Windows then in the Paper Tab
section continuous should be
selected.
Media out
Install a Media roll
Media not installed
Install a media roll
Media jam
Clear the jam
Verify that the media is routed
correctly.
Printhead module is
not closed
Close and latch the
printhead module
Power and Ready LEDs alternate blinking
**
Possible Problems Solutions
Remarks
Ribbon has run out
Supply the ribbon roll
Does not apply to direct thermal. If
you use direct thermal and run under
Windows the Ribbon should not be
selected.
Ribbon jam
Clear the jam
not for direct thermal
Ribbon sensor error Replace the ribbon sensor not for direct thermal
Note:
**
The FM402DT does not use a ribbon and should not display this error.
Only the Power LED blinks
Possible Problems Solutions
Remarks
Serial I/O error
Check the baud rate
Check the flow control
Memory full
Add the extension RAM
Cutter failed, or jam
at cutter
Check the cutter
Clear the jam
Only when cutter is installed.
Hardware error
Call for service