User's Guide 34
Command (Cont)
Description
Parameter
Ip1,p2,001
Select symbol set
**
p1: 7 or 8 data bits
p2: symbol set
JB
JF
Disable back feed
**
Enable back feed
**
LEx,y,hlen,vlen
Line draw by
exclusive
hlen: horizontal length
vlen: vertical length
LOx,y,hlen,vlen
Line draw by OR
LWx,y,hlen,vlen
Draw white line
N
Clear frame buffer
O[,C][,N][,D]
Select options
**
Pp1[,p2]
Print label
p1: label set number
p2: copy number of each label
PAp1[,p2]
Print automatic
Qp1,p2[,+p3]
Set label and gap
length
**
p1: label length
p2: gap length
p3: offset length
qw
Set label width
**
w: label width
Rx,y
Set origin point
**
Sp1
Set print speed
p1: speed value, 1 to 3
U
Print configuration
UN
US
Disable Error Report
Enable Error Report
Vvn,dn,just,string
Define variable
vn: variable index
dn: digit number
just: L,R,C and N for field justification
Xx,y,thick,ex,ey
Draw box
ex, ey: end position
thick: line thickness
Ybaud
Setup serial port
**
baud: 38,19,96,48 or 24
ZT
ZB
Set print direction
ZS: print from top
ZB: print from bottom
ZS
ZN
Enable/disable
store-to-Flash
++
power-on default is ZN(disabled)
?
Download variables
or counters