beautypg.com

3 power requirements, Power requirements – ADLINK cPCI-6615 User Manual

Page 24

background image

10

Specifications

2.3

Power Requirements

In order to guarantee stable operation of the system, it is recom-
mended that significantly more power be provided than required.
An industrial power supply unit should be able to provide at
least twice as much power as the entire system requires of
each voltage
. An ATX power supply unit should be able to provide
at least three times as much power as the entire system requires
of each voltage.

The tolerance of the voltage lines described in the CompactPCI
specification (PICMG 2.0 R3.0) is +5%/-3% for 5, 3.3 V and ±5%
for ±12V. This specification is for power delivered to each slot and
it includes both the power supply and the backplane tolerance.

Voltage

Nominal

Value

Tolerance

Max. Ripple

(P - P)

5V

+5.0 VDC

+5% / -3%

50 mV

3.3V

+3.3 VDC

+5% / -3%

50 mV

+12V

+12 VDC

+5% / -5%

240 mV

-12V

-12 VDC

+5% / -5%

240 mV

V I/O (PCI I/O

Buffer Voltage)

+3.3 VDC or

+5 VDC

+5% / -3%

50 mV

GND