ADLINK cPCI-6615 User Manual
Page 22

8
Specifications
1. Hard drive limits operational vibration. When application requires
higher vibration specification, it is recommended to use a flash disk.
2. ADLINK-certified thermal design. The thermal performance is
dependent on the chassis cooling design. Forced airflow with
3.2 m/s is required. Temperature limit of optional mass storage
devices may affect the thermal specification.
PMC
• One PCI-X 64-bit/133MHz PMC site
Audio
• High Definition Audio signal by Intel ICH8M routed to J3
Faceplate I/O
4HP (cPCI-6615):
• 3x USB 2.0 ports
• 3x 10/100/1000BASE-T Ethernet ports
• 1x RS-232/422/485
8HP (cPCI-6615D):
• 4x USB 2.0 ports
• 3x 10/100/1000BASE-T Ethernet ports
• Analog DB-15 VGA port
• 1x RS-232/422/485
• 1x RS-232
• PS/2 Keyboard/ Mouse combo port
OS
Compatibility
• Microsoft Windows XP, 7 32/64-bit
• Wind River VxWorks 6.8 w/SMP
• Red Hat Enterprise Linux 6
• Other OS support upon request
Power
Requirement
• 5V only for power up
Environmental
• Operating Temperature (with forced air flow)
2
:
- Standard: 0°C to 60°C
- Extended: -20°C to 85°C
Storage Temperature: -40°C to 85°C
• Humidity: 95% non-condensing
• Shock: 15G peak-to-peak, 11ms duration, non-operating
• Vibration
1
: Operating 2Grms, 5-500Hz, each axis w/o HDD
EMI
• CE EN55022
• FCC Class A
NOTE:
NOTE:
Specifications are subject to change without prior notice.