beautypg.com

3 cpci-6520 front panel, Status leds, General purpose leds – ADLINK cPCI-6520 User Manual

Page 35: Cpci-6520 front panel, Figure 4-3: cpci-6520 front panel, Status leds general purpose leds

background image

Board Interfaces

23

cPCI-6520

4.3

cPCI-6520 Front Panel

Figure 4-3: cPCI-6520 Front Panel

Status LEDs

General Purpose LEDs

In default mode, these eight LEDs display the POST codes output
to Port 80h during system bootup. For example, if the Bit7 > Bit0
output is “01110101”, then the port 80h output is “75h” (See
“Checkpoints & Beep Codes” on page 105).

LED

Color

Condition

Indication

Power

Green

OFF

System is off

ON

System is on

Blink

Fail to power on
(payload power failure)

HotSwap

Blue

OFF

Handles closed, System is on

Fast Blink

Preparing to shut down system
(LED: 0.1s on, 0.9s off.)

ON

Handles open and blade ready
to be removed

Slow Blink

Voltages out of tolerance:
3.3V, 5V, 12V, 1.5V over ±5%
(LED 2s on, 1s off)

WDT

Red

OFF

No Watchdog event

ON

Watchdog event alert

HDD

Amber

OFF

No drive activity

Blink

SATA, CF data read/write in
process

Status
LEDs

PMC/XMC

COM1

DisplayPort

Reset

Button

GbE 1/2

USB 3.0

General

Purpose LEDs