108
Checkpoints & Beep Codes
0x3B
Post-Memory South Bridge initialization is
started
0x3C
Post-Memory South Bridge initialization (South
Bridge module specific)
0x3D
Post-Memory South Bridge initialization (South
Bridge module specific)
0x3E
Post-Memory South Bridge initialization (South
Bridge module specific)
0x3F-0x4E
OEM post memory initialization codes
0x4F
DXE IPL is started
PEI Error Codes
0x50
Memory initialization error. Invalid memory type
or incompatible memory speed
0x51
Memory initialization error. SPD reading has
failed
0x52
Memory initialization error. Invalid memory size
or memory modules do not match.
0x53
Memory initialization error. No usable memory
detected
0x54
Unspecified memory initialization error.
0x55
Memory not installed
0x56
Invalid CPU type or Speed
0x57 CPU
mismatch
0x58
CPU self test failed or possible CPU cache error
0x59
CPU micro-code is not found or micro-code
update is failed
0x5A
Internal CPU error
0x5B
reset PPI is not available
0x5C-0x5F Reserved
for
future AMI error codes
S3 Resume Progress
Codes
0xE0
S3 Resume is stared (S3 Resume PPI is called
by the DXE IPL)
0xE1
S3 Boot Script execution
0xE2 Video
repost
Status Code
Description