Command Set

• 63

Note : When you want to change the checksum or baud rate then the

DEFAULT* pin should be grounded at first.

@Example

User command:

%0130400600

Response:

!30

Item

Meaning

Description

%

(Leading Code)

Command leading code.

01

(OldAddr)

Original address ID is 01H.

30

(NewAddr)

New address ID is 30H
(Hexadecimal).

40

(TypeCode)

Digital I/O module.

06

(BaudRate)

Baud rate is 9600.

00

(CheckSumFlag)

00 means checksum is disable.

Carriage return

0x0D.

Code

Baudrate

03

1200 bps

04

2400 bps

05

4800 bps

06

9600 bps

07

19200 bps

08

38400 bps

09

115200 bps

Table 0-1 Baud rate setting code

Table 0-2 Check sum flag setting

7

6

5

4

3

2

1

0

Reserved
Must to be 0

Checksum
0 : disable
1 : enable

Reserved
Must to be 000000