Introduction

• 7

1.3

Overview of NuDAM -6052

1.3.1

What is NuDAM-6052 ?

NuDAM-6052 provides 8 isolated digital input channels. Six of the input
channels are differential type and two of them are single-ended with
common ground. The isolation voltage is up to 5000 Vrms. It is suitable to
use NuDAM-6052 in industrial environment with the dangerous of high
voltage electric shock.

1.3.2

Features of NuDAM-6052

8 bits isolated input

5000 Vrms isolation voltage

Programmable host watchdog timer for host failure protection

Internal watchdog timer for device failure protection

Easy programming by software

Easy installation and wiring

1.3.3

Specifications of NuDAM-6052

Interface

Interface : RS-485, 2 wires

Speed (bps) : 1200, 2400, 4800, 9600, 19.2K, 38.4K, 115.2K
(115.2K only for firmware reversion above A4.00)

Input

Channel numbers : 6 differential channels, 2 single ended

Logical level 0 : +1V Max.

Logical level 1: +3.5V ~ +24V

Watchdog Function

Module internal watchdog timer : 150ms

Power failure threshold : 4.65 V