LEF all-master systems are designed to be wired in a looped fashion from the first to last master. Number of conductors for a full
system (not including “K” terminals) are:

■ LEF all-master configurations

Model

Cable

Wire number

LEF-3

9 conductors

#822210 in USA

LEF-5

12 conductors

#822212 in USA

LEF-10

17 conductors

#822220 in USA

LEF-10S

20 conductors

#822220 in USA

LE Subs

3 conductors

#822203 or #821803 in USA

• Single-master system can be wired with 2 conductors homerun from each

sub. (Wire #822202 or #821802 in USA)

■ Cable requirements

Use multi-conductor cable with an overall shield, non-twisted, 22AWG to 18AWG (0.65mm to 1.0mm), to accommodate the
maximum number of LEF master stations, LE subs, audio or PanTilt door(s), or 8i2 paging zones, each of which requires one

designated wire.

■ Power supply

Entire LEF system can be powered by one PS-12C (or PS-12A) power supply, located near the center of the truckage cable.
For a system including All-Call, Chime, & Music with the BG-10C, use a PS-12F power supply (12V DC, 2.5A) to power the entire
system.

Wiring diagrams

' LEF-3 with 2 Subs, 1 Door,

and External Signalling

LEF-3

★ Shorting link on E - - terminals

must remain attached on all units.

13^ ■ PS-12C or PS-12A

• Two LEF-3 and 2 Doors

LEF-3

LEF-3

* Shorting link E - - terminals

is removed on all units.

I: PS-12C or PS-12A

This manual is related to the following products: