TECHNICAL PRECAUTIONS----------------------------------------------------------------------
IMPORTANT:
•
Aiphone Corporation is not responsible for improper installations of ifs producf which result in interference generated by
dimmer switches, fluorescent lighting fixtures or other similar electrical devices. Any such installation must be corrected at the
source by the installing party. Aiphone also recommends that when installing any of its communication products that the
intercom wiring be run at least 20 inches (50 cm) away from any AC wiring.
•
In LEF/MY video system, run a separate LEF audio cable and MY video cable. Using the same cable for both audio and
video systems will cause severe interference with the LEF audio communications.
•
Clean your LEF equipment with a soft cloth dampened with neutral household cleanser.
Never use any abrasive cleaner or cloth.
SPECIFICATIONS (LEF)
Power source:
Communication:
Talk channel:
Output:
Wiring:
Key-mark button contact:
Select switch contact:
Wiring distance:
Dimensions & weight:
LEF-5, 10, 10S:
12V DC, 300mA per station.
Use a PS-12A or PS-12C or PS-12F power supply, 1 per system.
Press-to-talk, release-to-listen at master station.
• Master-to-master calling does not turn on station LED.
1 channel. Occupied LED is lit when system is in use.
800mW at 200 (reception). 500mW at 200 (transmission).
• Single-master system: 2 wires homerun.
• Between LEF masters: Min. 5 common* + total No. of sfations in fhe system, looped
(See pg. 4)
* 9 common wires including All Call and door release -i- total No. of stations in the system.
• Intermixed system: 3 wires per sub, homerun to the nearest master, or 2 common -r 1
individual wire per sub, looped.
30V DC, 0.1A (resistance load).
12V DC, 30mA (for exfernal device control).
0.65mm ^
0.8mm?f
I.Omm^i
200m
300m
480m
22AWG
20AWG
18AWG
650'
1,000’
1600'
LEF-3:
180 H X 143 W X 55 D (mm). 7-1/16" H x 5-5/8" W x 2-3/16" D.
420g, 0.93 lbs. approx.
206 H X 190 W X 55 D (mm). 8-1/8" H x 7-1/2" W x 2-3/16" D.
550g, 1.21 lbs. (LEF-5). 650g, 1.43 lbs. (LEF-10, 10S).
4-
•F
•F
•F
-F
•F
•F
•F
-F
-F
-F
-F
•F
•F
•F
-F
-F
•F
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and ser\rice for a
period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it
become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself
the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the
product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in
violation of instrucfions furnished, nor exfended to units which have been repaired or altered outside of the factory. This
warranty does not cover batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in vi/riting by
Aiphone.
Aiphone wili not be responsible for any cosfs incurred involving on site service calls.
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
LEF-I(E) 0896K
©
COMMUNICATION SYSTEMS
AIPHONE
HOME, BUSINESS, INDUSTRY.
Printed in Japan (E)