Features, Installation, Wiring – Aiphone LC-5S User Manual

Page 2: Wiring required

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

* Power source:

Master Station:

* Current consumption:

* Output:

* Master station calling:

* Wiring:

SPECIFICATIONS:

DC 6 V. Use PS—2S (CS—12A in North America) power supply per system. If one master

only is used in a system which includes several sub stations, power supply PS—3 (CS—6A in

North America) may be used; or, units may be powered by 4 standard “D” batteries placed
in each LC—5S or LC—lOS, and 4 standard “C” batteries placed in each LC—3S.

160 mA plus N X 40 mA for an entire system. (N shows number of master stations.)

LC-3S

220 mw, 20i2

LC-5S and LC-1 OS 400 mw, 20D.

Push button station selection. Occupied and on lamps indicate when the system is in use.

Up to 16 conductor cable may be required. Please refer to the instructions and wiring diagrams

to design a system that meets your requirements.

FEATURES:

* Highest manufacturing standard ensures outstanding reliability with trouble free operation.

* Single channel system.

* Hands free remote reply; a call received at an open voice station — if no privacy is required

where in a room without touching the instrument (range approximately 20 feet).

can be answered from any-

“Privacy” button; no monitoring or “eavesdropping” is possible on a station in privacy switch position. A call can still be
received and answered upon unlocking of the privacy button.

A wide choice of substations; seven substations are available to meet individual requirements.

Designed for either desk or wall mounting.

Simple push button operation with volume control for fingertip adjustment.

Excellent voice fidelity due to well engineered and perfectly matched amplifiers.

Master-to-master call by tone or voice direct (LC—3S voice only).

Master receives call from substation by tone and lamp annunciation.

INSTALLATION

Do not attempt to install your intercom system until you have read and thoroughly understood the installation

procedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.

WIRING

Lay out your system in advance. Determine the exact location of each station. Make yourself a sketch showing

the number of wires required from each station.

WIRING REQUIRED

LC—lOS — 16 conductors maximum.

LC—5S — 11 conductors maximum.

LC—3S

7 conductors

maximum.

V—A

2 conductors

from V—A to selected master.

V—B

2 conductors

from V—B to selected master.

V—AN

— 2 conductors from V—AN to selected master.

V—L

2 conductors

from V—L to selected master.

V—A2

3 conductors

required; one common and one

to each of two selected

masters.

V—A4

5 conductors

required; one common and one

to each of four selected

masters.

Refer to the chart below and select the proper wire gauge to meet your requirements.

AWG WIRE SIZE

24 AWG

22 AWG

20 AWG

18 AWG

DISTANCE

400'

650'

1000'

1600'

DIAMETER OF WIRE

0.5 mm

0.65 mm

0.8 mm

1.0 mm

DISTANCE

120 m

200 m

300 m

400 m