2 t/8 – Bryant PAYNE 619C User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
■ À
To install this system you will need:
1 — 619C fan coil
1 — 700C or 705C outdoor unit
1 — Remote controller kit (included with 619C fan coil) —
note that kit normally includes 15-ft long wire cable;
however, cable length up to 200 ft can be ordered.
1 — Low Ambient Kit (if required for your application)
1 — Check-Flo-Rater™ Metering Device Kit (included with
619C fan coil)
1 — Fresh-Air Intake Kit (if required for your application)
1 — Condensate Pump Kit (if required for your application)
NOTE:
Refrigerant pipe, drain pipe, wire, etc., are also re
quired to install system.
Be sure you have the required parts before beginning instal
lation. The 619C unit utilizes a microprocessor control sys
tem to deliver optimal levels of comfort and efficiency. Be sure
to follow these instructions carefully to obtain proper func
tioning of the unit.
B. Inspecf^hipmeiit
Upon receipt of shipment check unit for damage. Forward claim
papers directly to the transportation company. Manufac
turer is not responsible for damage incurred in transit.
Check all items; if any item is missing notify your distribu
tor. To prevent loss or damage, leave all parts in original pack
ages until installation.
C. Before Installation
Perform the following steps before installing indoor unit
(Fig. 2). Place the unit upside down on the floor, then:
1. Remove side panels by sliding forward, then away from
sides of unit.
2. Remove air filters from inlet grilles; then remove and
retain screws securing inlet grilles to indoor unit.
3. Remove inlet grilles from indoor unit by sliding
forward.
Table 2 - Application Range
COOLING
Maximum
Minimum
Indoor
Outdoor
Indoor
Outdoor
95 F DB
71 F WB
125 F DB
67 F DB
57 F WB
55 F DB*
HEATING
Maximum
Minimum
Indoor
Outdoor
Indoor
Outdoor
80 F DB
71 F WB
75 F DB
65 F WB
55 F DB
-20 F DB
LEGEND
DB — Dry Bulb
WB - Wet Bulb
'Unit may be equipped with a iow-ambient control that will allow
operation down to ~20 F
I. COMPLETE PRE-INSTALLATION CHECKS
A. Unpack Unit
Store unit in the original packaging until it is moved to the
final site for installation. When removing unit from carton,
lift unit by its 4 corners; DO NOT lift unit by its plastic parts.
LOOSEN eOLTS
AND
SLIDE-
MOUNTING
BRACKET
THIS
DIRECTION—TO REMOVE
2 T/8
tSSJ
DISCHARGE AIR
SLIDE SIDE PANEL THIS
OIRECTION—TO REMOVE
PIPING JOINT
(LIQUID SIDE)
PIPING JOINT
(VAPOR SIDE)
REMOVABLE AIR FILTER
PIPING
KNOCKOUT
(RIGHT SIDE)
[INLET AIR
'-DRAIN CONNECTION
NOTE: Dimensions shown in brackets [ ] are in mm
Fig. 2 — Removal of Mounting Brackets
from Indoor Unit
Table 3 — Physical Data
UNIT 619C
NX0240E0
NX0360E0
NX0480E0
NX0240W0
NX0360W0
NX0480W0
OPERATING WT (lb)
108
117
140
110
119
142
REFRIGERANT
R-22, Check-Flo-Rater Control
FAN
Rpm
High
1035
1310
1345
1035
1310
1345
Med
990
1160
1307
990
1160
1307
Low
940
1010
1270
940
1010
1270
Nominal Cfm (High Speed)
635
935
1300
635
935
1300
COIL
Rows
4
4
4
4
4
4
Face Area (sq ft)
2.189
2.625
3 069
2 189
2.625
3.069
FIns/in.
149
149
14.9
14.9
14.9
14.9
Number of Circuits
4
4
8
4
4
8
CONNECTIONS
Suction (in.) Flare
%
3/4
3/4
3/a
3/4
3/4
Liquid (in.) Flare
%
3/a
3/a
3/a
Ve
3/a
Condensate Drain (in.)
%
3/4
3/4
3/4
3/4
3/4
LINE SIZES
Suction (in.)
%
3/4
%
Va
3/4
%
Liquid (in.)
%
%
%
3/e
3/a
3/a
Condensate Drain
3/4
3/4
3/4
3/4
3/4
3/4
-
2
-