NOTES FOR FIG. 20 AND 21

1. Compressor and fan motor are thermally protected.

2. Wire in accordance with National Electrical Code (NEC)

and local codes. If any of the original wire must be re­

placed, it must be replaced with type 90 C wire or its

equivalent.

3. Use minimum of 60 C wiring for field power wiring.

4. Thermostat is internal to unit. Unit must be controlled

with wired or infrared wireless remote controller.

5. Use copper conductors only.

LEGEND FOR FIG. 20 AND 21

ASM

_

Air Sweep Motor

IDC TH

_

Indoor-Coil Thermistor

Circuit Board Run

ASR

Air Sweep Reiay

IFM

Indoor-Fan Motor

C

_

Compressor Contactor

LPS

Low-Pressure Switch

Terminal Marked

CAP

Capacitor

OATTH

Outdoor Air Thermistor

o

CB

Circuit Breaker

OCTTH

Outdoor Coil Thermistor

Terminal Unmarked

CH

Crankcase Heater

OFM

Outdoor Fan Motor

COMP

Compressor

OFR

Outdoor Fan Relay

Splice

DATTH

Discharge Air Thermistor

PCB

Printed Circuit Board

DTS

Discharge Temperature Sensor

PL

Plug

1

>■

1

Terminal Block

EQUIP

Equipment Ground

RA TH

Return Air Thermistor

GND

RVS

Reversing Valve Solenoid

Factory Wiring

FL

Fuse Link

SC

Start Capacitor

HPS

High-Pressure Switch

SR

Start Relay

Field Control Wiring

HR

Heater Relay

TB

Terminal Block

Field Power Wiring

HTR

Heater

TDR

--

Time-Delay Relay

HTT

Heater Temperature Thermostat

TRAN

Transformer

Accessory or Optional Wiring

-