Single-phase heaters three-phase heaters, Three-phase heaters, Based on 60°c copper wire. see table ii – Bryant 559B User Manual

Page 12: Circuita to fused disconnect circuit

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TO FUSED

DISCONNECT

TO FUSED

DISCONNECT

TO FUSED .

DISCONNECT

KW

Voltage-

Phase

Circuits

Used

Wire

Size*

5

240-1

1

A

10

7.5

240-1

1

A

8

10

240-1

1

A

6

15

240-1

2

A

6

B

. 10

20

240-1

2

A

6

B

6

25

240-1

3 .

A

6

B

6

C

10

*Based on 60°C copper wire. See Table II.

SINGLE-PHASE HEATERS

THREE-PHASE HEATERS

(PIGTAIL CONNECTIONS)

CIRCUITA

TO FUSED

DISCONNECT

CIRCUIT

B

TO FUSED

DISCONNECT *Based on 60°C copper wire. See Table II.

THREE-PHASE HEATERS

(TERMINAL BOARD CONNECTIONS)

KW

Voltage-

Phase

Circuits

Used

Wire

Size*

25

208-3

2

A

'6

B

6

14.9/19.8

208/240-3

1

A

6/4

18.75/25

208/240-3

2

A

8/8

B

8/8

20

480-3

1

A

10

LEGEND

FACTORY LINE-VOLTAGE WIRING

FIELD LINE-VOLTAGE WIRING

FIELD SPLICE

Figure 10—Line-Power Connections

-