AutoStore or Power Up RECALL

Parameter

Alt

Description

STK14C88-3

Unit

Min

Max

t

HRECALL

[15]

t

RESTORE

Power up RECALL Duration

550

μs

t

STORE

[16, 17]

t

HLHZ

STORE Cycle Duration

10

ms

t

VSBL

[16]

Low Voltage Trigger (V

SWITCH

) to HSB low

300

ns

V

RESET

Low Voltage Reset Level

2.4

V

V

SWITCH

Low Voltage Trigger Level

2.7

2.95

V

t

DELAY

[16]

t

BLQZ

Time Allowed to Complete SRAM Cycle

1

μs

Switching Waveforms

Figure 11. AutoStore/Power Up RECALL

WE

Notes

15. t

HRECALL

starts from the time V

CC

rises above V

SWITCH

.

16. CE and OE low and WE high for output behavior.
17. HSB is asserted low for 1us when V

CAP

drops through V

SWITCH

. If an SRAM WRITE has not taken place since the last nonvolatile cycle, HSB will be released and no

store will take place.