23903
Page 8 of 32
3) Auto manual-speed and the indication
Shutter dial M
Shutter speed tester (7F-9A-
a.
Check the curtain speed at 1/l000sec.. 6.5ms or faster at 21mm
distance
b.
Check each shutter speed from 1/2000 sec. ~ 4 sec..
c.
Each LED should be turned on when changed the shutter speed, and
OVER or UNDER LED must be flickering when non-proper exposure was
made.
*As a general rule, use Light value correction unit and Shutter speed
tester (7F-9A-2) for checking and/or adjusting the shutter speed and the
indication. However, Shutter speed tester (7PE-25A3) may use by the
circumstances.
4) LED indication and Shutter speed under the full-charged condition of AF-
2OOS or AF-160
When load 2.4V between the ground and Hot shoe contact piece A (N4), LED
indication and the shutter speed are as below.
a. LED indication
M — flickering
125X — on
b. Shutter speed
9.6 -— 11.8ms
5)
Battery check
2.4V
LED off or flickering
2.65V
LED on
18.
Remove ASA ring and the temporary top cover
19.
Clean the view-finder
*Do not use the air-compressed blower to clean the view-finder. It will
be caused by taking out Shutter speed indication plate (M10).
20.
Top cover assy. (A300)
Check the conductivity of Switch board (A318) before install Top cover
assy. (A300).
a.
At Shutter dial AUTO
A
— the ground
ON
B
— the ground
OFF
C
— the ground
OFF
a.
At Shutter dial M
A
— the ground
OFF
B
— the ground
OFF
C
— the ground
OFF
When pushed the bottom side button,
B
—
the ground
ON
When pushed the up side button,
C
— the ground
ON