2) LED positioning
Use P.C. board pattern checker (239 PATTERN CHECKER). Adjust LED
position by sliding the LED supporting plate.
Each LED should be aligned with its figure in the view-finder.
3) As installing Photo-cell part to Cell frame (N1), insert P.C. board to
the connector.
4) Photo-cell part
Hot shoe contact piece C (N9)
T-CNL-E 1.7 x 3
Insulation plate (Nl3)
Insulation collar (N8)
Hot shoe contact piece A (N4)
T-CNL-E 1.7 x 4
8.
Front board and Mirror housing
Shutter block
charged condition
Mirror housing
released condition
*lAThen installed, take care about lead wires.
Front board retainer screw (A132-01) 4pcs.
W14
P. C. board retainer (I1)
CNL-Dl.7 x 3 x 2
After installed, check the functions of shutter.
9.
Mechanical back focus.
45,46 ± 0.04mm
10. Soldering
The location of solder
refer to page 1 and 2.
Especially, red and blue lead wire should be positioned
between Relay P.C. board assy. (0-A129) and Prism seat
assy. (0-M2), as shown left. — to prevent from catching
between the top cover and the prism seat.
11. ASA volume (R100)
ASA volume retainer scerw (A16-01)
CNL-D 1.7 x 2. 5
12. Bottom cover assy. (A400)
Connector seat (A23)
Bottom cover assy. (A400)
CSS 1.7 x 3 x 2
CSS 1.7 x 2.2
13. Load the batteries
G13 x 2