Pentax me super User Manual
Page 4
23903
Page 3 of 32
*PC board pattern (T100)
LED part in P. C. board pattern (T100) should be taken out straight and
carefully to prevent making scratches on Shutter speed scale indication
plate (M10).
*P.C. board pattern (T100)
It is recommended that P.C. board pattern (T100) is taken out
from Mirror housing under the condition separated from Body
proper (A1). due to difficulty of LED part taken out and/or
installed.
Assembly and Adjustment
1.
Cocked indicator assy. (0-C23) Check the spring tenSion.
At the released condition, the spring should have no tension.
If the spring tension is stronger at the charged condition, 2nd curtain
speed will be affected. Accordingly, 1/2000sec will be changed by its
spring tension. (l/2000sec should be not changed by its spring
tension.)
2. Adjustment of Main SW
At the condition of release plate assy. (A500)
goes
up completely, adjust 0.5mm clearance between
the
contact pieces by turning eccentric screw.
Adjust the clearance by eccentric screw in the range shown below to
prevent the side of screw touching the body when the shutter rod pushed
down or up.
If the clearance is wider
than 0.5mm, the shutter
will be stayed open at the
1st exposure when released
by Self-timer or Winder.
3.
EF- switch contact piece (A44)
The clearance of
A
should be within 0.3mm.
Adjust the clearance by bending the part of
B
.