Pentax me super User Manual
Page 10
23903
Page 9 of 32
If the conductivity of Switch board (A318) was good, install Top cover
assy. (A300).
The point of installation is the same as 23900 ME.
Cover frame (A131)
Top cover retainer screw A (A333)
2pcs.
Top cover retainer screw B (A334)
Top cover retainer screw C (A332)
2pcs.
Top cover retainer screw D (A335)
After installed, check the function of LED by changing the shutter
dial.
21.
ASA ring assy. (0-D11-01), Rewinding knob assy. (0-D6)
ASA ring assy. (0-D11-01)
Washer (D21)
Nut (D15)
After installed, check the function of click of ASA ring assy. (0-D11-
01). and the LED indication.
At 1/4X, 1/2X, 2X and 4X except 1X, EF red LED must be flickering. If
not, check the clearance of ElF switch contact piece (A44) and lead
wires and/or adjust ElF index plate (D23) assembled in ASA ring assy.
(0-D11-01), as shown below.
0-D11-01
D23
Fix D23 as pushing to the
arrowed
direction
Rewinding knob assy. (0-D6)
22.
Winding lever assy. (0-C69)
Winding lever friction spring (C7-01)
Winding lever assy. (O-C69)
Winding lever nut (C8)
left handed
23600K0C134-A-2
Cover screw (C139-01)
left handed
23600K-C135-A
Check the function of shutter and winding.
23.
Check the shutter button stroke Shutter dial Bulb
a.
When pushed the shutter button deeper than 0. 2mm from the original
position, LED should be turned ON before release the shutter.
Main switch ON position
b.
After released 1st curtain, the shutter button can goes down
0. 1 - 0.5mm.