beautypg.com

Trouble shooting guide - motor, Trouble shooting guide; -25, Trouble shooting guide - gene – Sears 113.23522 User Manual

Page 24: T as

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Trouble Shooting Guide - Motor

PnOSLEM

PROBABLE CAUSE

SUGGESTED CORRECTIVE ACTION

Brake does not stop
blade within
6 seconds.

1 Brushes not seated

or lightly sticking.

2.. Motor brake winding-

overheated from use of not-

recommended blade

or rapid on/off cycling.

3 Arbor screw loose,
4 Other

-Inspect/clean/replace brushes

(see maintenance section).

-Use a recommended blade
-Let coo! down

-Retighten
-Authorized service. Check motor brake winding,

switch, condition of commutator

Motor does not start.

1 Fuse.

2. Brushes worn.
3, Other

-15-Amp time delay fuse, or circuit breaker
-See “Maintenance" section,
-Authorized service.

Brush sparking when
switch released.

1 Normai-automaiic brake

working properly

-None

Trouble Shooting Guide - Gene

....................................

t aS

................................ ' " ..............

PROBLEM

PROBABLE CAUSE

SUGGESTED CORRECTIVE ACTION

Blade hits table.

1 Misalignment.

-Get authorized Sears Service.

Angle of cut
not accurate.

1 Misalignment

-See "Alignment" section.

Can’t move
miter adjustment

1 Sawdust under table

-Vacuum or blow out dust,

WEAR EYE PROTECTION

Power-head

wobbles.

1 Loose pivot points

-See “Alignmenf section

Power-head
won’t fully rise or blade
guard won’t fully close.

1 Part failure.,

2. Pivot spring not replaced

properly after service

3 Sawdust build-up

-Get authorized Sears Service.
-Get authorized Sears Service­

-Clean and lubricate moving parts.

Blade binds, jams,
burns wood.

1. Improper operation.

2 Dull blade.
3 Improper blade

4, Warped blade

-See “Basic Saw Operation" section.

-Replace or sharpen blade.
-Replace with 10" diameter blade designed

for the materia! being cut.

-Replace blade.

Toot vibrates or

shakes*

1 - Saw blade not round.

2. Saw blade damaged.
3, Saw blade loose,-
4 Other.

-Replace blade.
-Replace blade
-Tighten arbor screw.
-Get authorized Sears Service.

Power head is difficult

to move down from

upper stop.

1 Mechanism which pivots

lower guard is sticking,

2 Sawdust build-up in

guard area,

-Clean and lubricate lower guard mechanism

(See lubrication Instructions on page 22)

-Clean and lubricate lower guard mechanism (See

lubrication instructions on page 22)

24

This manual is related to the following products: