Fig. 2—dimensional drawing, Fig. 3—floor opening for concrete slab, A warning – Carrier 58DR User Manual

Page 2: Table 4—opening dimensions, Furnace ■plenum

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

1

5. ^

r'

/

8 THERMOSTAT CONN

— -?>•

o

:

a

KNOCKOUT

AUX GAS

INLET

Table 2—Dimensions (In Inches)

Size

A

D

E

Vent

050-BA

14^6

12"/,e

12”/,6

4

075-AA

17^2

15^

16

4

075-BA

M'k

15%

16

4

100-AA

M'b

15%

16

5

100-BA

17Ya

15%

16

5

125-AA

21

19%

19Ya

5

125-BA

21

19%

19%

5

150-BA

2A'k

22%e

23

6

AIRFLOW

A78595

Fig. 2—Dimensional Drawing

Table 3—Ratings and Performance

Size

input

Btuh*

Capacity

Btuht*

Temp

Rise

Range

Heating

Cooling

Motor

HP&

Type

Approx

Shipping

Weight

Ext Static

Pressure

CFM

Ext Static

Pressure

CFM

050-BA

50,000

39,000t

45—75

0.50

600

0.5

800

73-SP

129

075-AA

75,000

58,000

70—100

0.12

630

%0-SP

148

075-BA

45—75

0.50

895

0.5

1255

%-SP

157

100-AA

100,000

78,000t

70—100

0.20

850

Vs-SP

163

100-BA

60—90

0.50

960

0.5

1630

%-PSC

170

125-AA

125,000

97,000t

70—100

0.20

1050

%-SP

187

125-AA

60—90

0.50

1195

0.5

1620

%-PSC

187

150-BA

150,000

116,000t

55—85 ,

0.50

1535

0.5

2075

Ya-PSC

227

*The above gas input ratings are certified for eievations to 2000 ft. For elevations above 2000 ft, reduce input 4% for each 1000 ft above sea ievei.
tDetermined by U.S. Government tests.

tDeduct 1000 Btuh for Modei58DR.

, '

;

A73382

Fig. 3—Floor Opening for

Concrete Slab

This furnace is designed for a minimum continuous return
air temperature of 60 degrees F DB or an intermittent oper­
ation down to 55 degrees F DB such as when used with a
thermostat night setback. Return air temperature must not
exceed a maximum of 85 degrees F DB.

A WARNING

Improper histaUation, adjustment, alteration, service,

maintenance, or use can cause carbon monoxide poison­
ing, explosion, fire, electrical shock, or other conditions
which may cause personal injury or property damage.
Consult a qualified installer, service agency, local gas
supplier or your Distributor or Branch for information
or assistance. The qualified installer or agency must use
only factory authorized and listed kits or accessories

when modifying this product. A failure to adhere to this
warning can cause electrical shock, fire, personal injury,
or death.

Table 4—Opening Dimensions

Furnace Casing

A

B

Width

Heat-Only

Heat/Cool*

14%s

13%

19=/s

197,6

17%

167,6

19%

. 197,6

21

19%

19%

197,6

24%

237,6

19%

197,6

♦These dimensions appiy when a Model 28RC or RD Evaporator Coil cas­

ing is to be installed.

FURNACE

■PLENUM

A73383

Fig. 4—Furnace on a Concrete Siab