beautypg.com

Fig. 9—wiring diagram (iid pilot) – Carrier 58DR User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

FUSED DISCONNECT

SW ITCH (WHEN REQ'D)

ILK SWITCH

TRAN

CAP

(WHEN USED)

TO THERMOSTAT

BREAKAWAY TAB REMOVED WHEN CONNECTING VENT DAMPER (SEE INSTALLATION INSTRUCT IONS)-

YEL

LOD-

CWHEN USED)

NOTES:

m

DOWNFLOW FURNACES ONLY

I.

I----

rz

—I

HEATING FAN RELAY CONTACT IS

•-rkF* NORMALLY CLOSED UNTIL 115V AC IS

HFR APPLIED TO FURNACE.

TO CHANGE MOTOR SPEED, MOVE RED WIRE TO
DESIRED SPEED SETTING.

IF ANY OF ORIGINAL WIRE AS SUPPLIED WITH

THE APPLIANCE MUST BE REPLACED, IT MUST

BE REPLACED WITH AWM C105°C) WIRE OR ITS
EQUIVALENT.
MOTOR IS THERMALLY OVERLOAD PROTECTED.
FACTORY SPEED SELECTION IS FOR AVERAGE
CONDITIONS, SEE INSTALLATION INSTRUCTIONS

FOR OPTIMUM SPEED SELECTION. MOTOR MAY
BE 3 OR 4 SPEED.
SYMBOLS ARE ELECT. REPRESENTATION ONLY.
FACTORY CONNECTED WHEN ACCESSORY NOT USED.

2

.

3.

4.

5.

6.

7.

LEGEND

ALS

CAP

CFR

FL

FU2

GV

HFR

ILK

LOD

LS

MTR

PCB

PI

SP

TRAN

VSS5

O

0

/ f y

AUXILIARY LIMIT SWITCH, MANUAL-RESET

C5PST-NC)

RUN CAPACITOR

COOLING FAN RELAY CDPDT

FUSIBLE LINK

FIELD FUSE

GAS VALVE

HEATING FAN RELAY CSPST-NC)
SWITCH, BLOW. DOOR INTERLOCK CSPST-NO)

LOCKOUt TIMER DEVICE CSPST-NO)

LIMIT SWITCH, AUTO.-RESET CSPST-NC)

MOTOR, BLOWER

PRINTED CIRCUIT BOARD

PILOT IGNITER

SAFETY PILOT (FLAME SENSING)
TRANSFORMER

VENT SAFETY SHUTOFF SWITCH, MANUAL-

RESET CSPST-NC)

FIELD SPLICE
PLUG RECEPTACLE
JUNCTION
UNMARKED TERMINAL
TERMINAL PCB FACTORY CONN.
FACTORY WIRING. C120V AC)
FACTORY WIRING CLOW VOLTAGE)
FIELD WIRING C120V AC)
FIELD WIRING C24V AC)

CONDUCTOR ON PRINTED CIRCUIT BOARD

SCREW TERMINAL FOR FIELD WIRING

FIELD GROUND

EQUIP. GROUND

ELECTRONIC

AIR CLEANER

(WHEN USED)

EAC-2

314296-401 REV. A

Fig. 9—Wiring Diagram (IID Pilot)

A89168

This manual is related to the following products: