Table 3 — Accessories

PART NO.

38CQ900081

38CQ900111

38QB90002106

38HQ9000011

28VQ900011

38RQ900081

38RQ900001

38HQ900002

38CQ900172

38RQ900091

DESCRIPTION

Low-Voltage Control — Honeywell Thermostat HH07AT171 and
Thermostat Subbase HH93AZ173 — (Automatic Changeover)

Low-Voltage Control — Honeywell Thermostat HH07AT171 and

Thermostat Subbase HH93AZ175 — (Manual Changeover)

Service Sentry (Six HN65CT004)

Hot Shot® Domestic Water Preheater

Twelve 3/4- x 1-1/8 in. connection adapters

Bi-Flow Heat Pump Filter Drier (Six KH45LD077)

Supplemental Heat Relay — (Required with 2 outdoor thermostats.)
(Service Parts)

Outdoor Thermostat (Six 38HQ9000101)

Optimizer Control Outdoor Thermostat (Six 38CQ900161 ref HH22AG110)

Optimizer II Control Assembly (Use with HH22AG110 outdoor thermostat.)

MODEL 38QB

All

r

042

All

38QB90000106

Heat Pump Rack

018

38QB90001106

Heat Pump Rack

024, 030, 036, 042

38HQ90014106

Optimizer III (Six 38HQ900141)

38CQ900141

Solid-State Time Guard It (24-volt)

All

HC95DD121*

Start Capacitor

018

HC95DD058*

Start Capacitor

HC95DD088*

Start Capacitor

024, 030

036

HN61HB515*

Relay

018

HN61HB496*

Relay

024, 030, 036

TUBING

PACKAGE

Length

Liquid

OD

Tube End OD

(ft)

(in.)

(in.)

(in.)

38LS958151

15

3/8

3/8

5/8

38LS958201

20

3/8

i ■ m

3/8

10

5/8

38LS958251

25

3/8

3/8

5/8

38LS958301

30

5/16

3/8

5/8

38LS958351

35

5/16

3/8;

5/8

38LS958401

40

5/16

3/8

10

5/8

38LS958501

50

1/4

ÍL

3/8

.... : 5/8

38LS934151

15

"IMd

3/8

3/8

ri^’ 3/4

38LS934201

20

3/8

3/8

I

3/4

38LS934251

25

3/8

I'-^.5?

3/8

I ’

3/4

38LS934301

30

3/8

r m ".

3/8

I 10

3/4

38LS934351

35

3/8

? ' '■

3/8

i ■ W

3/4

38LS934401

40

3/8

Í

3/8

10

3/4

38LS934501

50

3/8

3/8

10

3/4

38LS978151

15

3/8

3/8

' Í0

7/8^

38LS978201

20

3/8

3/8

10

7/8^

38LS978251

25

3/8

3/8

10

7/8^

38LS978301

30

3/8

3/8

10

7/8^

38LS978351

35

3/8

\

3/8

7/8^

38LS978401

40

3/8

1

3/8

^0

7/8*

38LS978501

50 '^<2

3/8

3/8

10

7/8*

TUBING

Suctionf

OD

n

45.7» I

ÍS79

ism

15.7»

mm

miss

ism I

ISiíSl

WM

Í0MI

15061

2a 22 I
22.a2i

2222

2ZZH i

22.22 S

i

Unit

38QB

018

024, 030

036, 042

•Available thru Carrier Service Parts
fSuction line is insuiated and has 90° bend
jpor 5/8-in (7.9-mm) evaporator connection, cut off 3/4-in. (19 05-mm) belled end

••Capacity reduction may occur when 7/8-in, (22 22-mm) accessory tubing is used on 38QB042

When other than 25 ft (7,6 m) of interconnecting

tubing is used, follow special requirements described

in Refrigerant Charging. Do not use less than 10 ft

(3 m) of interconnecting tubing. Do not cut 5/ 16-in.

(7.94 mm) or 1/4-in. (6.35 mm) liquid line due to

swage at ends. Do not cut 7/8-in. (22.22 mm)

suction line. Bend or coil to fit.

Do not use damaged or contaminated tubing.

Always evacuate or purge evaporator coil and

tubing system (use field-supplied refrigerant, not

unit refrigerant).

When making tubing connections, be sure to

provide clearance at unit for electrical connections.